Search Results (456 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-21424 1 Dell 1 Powerscale Onefs 2026-04-16 6.7 Medium
Dell PowerScale OneFS, versions prior to 9.10.1.6 and versions 9.11.0.0 through 9.12.0.1, contains an execution with unnecessary privileges vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.
CVE-2026-30225 1 Olivetin 1 Olivetin 2026-04-16 5.3 Medium
OliveTin gives access to predefined shell commands from a web interface. Prior to version 3000.11.1, an authentication context confusion vulnerability in RestartAction allows a low‑privileged authenticated user to execute actions they are not permitted to run. RestartAction constructs a new internal connect.Request without preserving the original caller’s authentication headers or cookies. When this synthetic request is passed to StartAction, the authentication resolver falls back to the guest user. If the guest account has broader permissions than the authenticated caller, this results in privilege escalation and unauthorized command execution. This vulnerability allows a low‑privileged authenticated user to bypass ACL restrictions and execute arbitrary configured shell actions. This issue has been patched in version 3000.11.1.
CVE-2025-50505 1 Clash-verge 1 Clash-verge 2026-04-15 7.8 High
Clash Verge Rev thru 2.2.3 (fixed in 2.3.0) forces the installation of system services(clash-verge-service) by default and exposes key functions through the unauthorized HTTP API `/start_clash`, allowing local users to submit arbitrary bin_path parameters and pass them directly to the service process for execution, resulting in local privilege escalation.
CVE-2024-13090 2026-04-15 7 High
A privilege escalation vulnerability may enable a service account to elevate its privileges. The sudo rules configured for a local service account were excessively permissive, potentially allowing administrative access if a malicious actor could execute arbitrary commands as that account. It is important to note that no such vector has been identified in this instance.
CVE-2025-22368 2026-04-15 N/A
The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS.
CVE-2024-11075 1 Sick Ag 1 Incoming Goods Suite 2026-04-15 8.8 High
A vulnerability in the Incoming Goods Suite allows a user with unprivileged access to the underlying system (e.g. local or via SSH) a privilege escalation to the administrative level due to the usage of component vendor Docker images running with root permissions. Exploiting this misconfiguration leads to the fact that an attacker can gain administrative control. over the whole system.
CVE-2024-6834 2026-04-15 9 Critical
A vulnerability in APIML Spring Cloud Gateway which leverages user privileges by unexpected signing proxied request by Zowe's client certificate. This allows access to a user to the endpoints requiring an internal client certificate without any credentials. It could lead to managing components in there and allow an attacker to handle the whole communication including user credentials.
CVE-2025-23395 2026-04-15 7.8 High
Screen 5.0.0 when it runs with setuid-root privileges does not drop privileges while operating on a user supplied path. This allows unprivileged users to create files in arbitrary locations with `root` ownership, the invoking user's (real) group ownership and file mode 0644. All data written to the Screen PTY will be logged into this file, allowing to escalate to root privileges
CVE-2024-8903 2026-04-15 N/A
Local active protection service settings manipulation due to unnecessary privileges assignment. The following products are affected: Acronis Cyber Protect Cloud Agent (Windows, macOS) before build 38565.
CVE-2025-6893 1 Moxa 7 Edf-g1002-bp, Edr-8010, Edr-g9010 and 4 more 2026-04-15 N/A
An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A flaw in broken access control has been identified in the /api/v1/setting/data endpoint of the affected device. This flaw allows a low-privileged authenticated user to call the API without the required permissions, thereby gaining the ability to access or modify system configuration data. Successful exploitation may lead to privilege escalation, allowing the attacker to access or modify sensitive system settings. While the overall impact is high, there is no loss of confidentiality or integrity within any subsequent systems.
CVE-2025-62876 1 Kde 1 Kde 2026-04-15 N/A
A Execution with Unnecessary Privileges vulnerability in lightdm-kde-greeter allows escalation from the service user to root.This issue affects lightdm-kde-greeter. before 6.0.4.
CVE-2025-24331 2026-04-15 6.4 Medium
The Single RAN baseband OAM service is intended to run as an unprivileged service. However, it initially starts with root privileges and assigns certain capabilities before dropping to an unprivileged level. The capabilities retained from the root period are considered extensive after the privilege drop and, in theory, could potentially allow actions beyond the intended scope of the OAM service. These actions could include gaining root privileges, accessing root-owned files, modifying them as the file owner, and then returning them to root ownership. This issue has been corrected starting from release 24R1-SR 0.2 MP and later. Beginning with release 24R1-SR 0.2 MP, the OAM service software capabilities are restricted to the minimum necessary.
CVE-2024-3330 2026-04-15 9.9 Critical
Vulnerability in Spotfire Spotfire Analyst, Spotfire Spotfire Server, Spotfire Spotfire for AWS Marketplace allows In the case of the installed Windows client: Successful execution of this vulnerability will result in an attacker being able to run arbitrary code.This requires human interaction from a person other than the attacker., In the case of the Web player (Business Author): Successful execution of this vulnerability via the Web Player, will result in the attacker being able to run arbitrary code as the account running the Web player process, In the case of Automation Services: Successful execution of this vulnerability will result in an attacker being able to run arbitrary code via Automation Services..This issue affects Spotfire Analyst: from 12.0.9 through 12.5.0, from 14.0 through 14.0.2; Spotfire Server: from 12.0.10 through 12.5.0, from 14.0 through 14.0.3, from 14.2.0 through 14.3.0; Spotfire for AWS Marketplace: from 14.0 before 14.3.0.
CVE-2024-3498 2026-04-15 7.8 High
Attackers can then execute malicious files by enabling certain services of the printer via the web configuration page and elevate its privileges to root. As for the affected products/models/versions, see the reference URL.
CVE-2025-22367 2026-04-15 N/A
The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.
CVE-2025-22366 2026-04-15 N/A
The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.
CVE-2025-9055 3 Axis, Axis Communications Ab, Linux 3 Axis Os, Axis Os, Linux 2026-04-15 6.4 Medium
The VAPIX Edge storage API that allowed a privilege escalation, enabling a VAPIX administrator-privileged user to gain Linux Root privileges. This flaw can only be exploited after authenticating with an administrator-privileged service account.
CVE-2025-1977 1 Moxa 2 Nport 6100-g2 Series, Nport 6200-g2 Series 2026-04-15 N/A
The NPort 6100-G2/6200-G2 Series is affected by an execution with unnecessary privileges vulnerability (CVE-2025-1977) that allows an authenticated user with read-only access to perform unauthorized configuration changes through the MCC (Moxa CLI Configuration) tool. The issue can be exploited remotely over the network with low-attack complexity and no user interaction but requires specific system conditions or configurations to be present. Successful exploitation may result in changes to device settings that were not intended to be permitted for the affected user role, potentially leading to a high impact on the confidentiality, integrity, and availability of the device. No impact on other systems has been identified.
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2025-14096 1 Radiometer 5 Abl800 Basic Analyzer, Abl800 Flex Analyzer, Abl90 Flex Analyzer and 2 more 2026-04-15 8.4 High
A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system. Other related CVE's are CVE-2025-14095 & CVE-2025-14097. Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency. Required Configuration for Exposure: Attacker requires physical access to the analyzer. Temporary work Around: Only authorized people can physically access the analyzer. Permanent solution: Local Radiometer representatives will contact all affected customers to discuss a permanent solution. Exploit Status: Researchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication.