| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An Uncontrolled Search Path Element issue was discovered in AzeoTech DAQFactory versions prior to 17.1. An uncontrolled search path element vulnerability has been identified, which may execute malicious DLL files that have been placed within the search path. |
| An issue was discovered in Sielco Sistemi Winlog Lite SCADA Software, versions prior to Version 3.02.01, and Winlog Pro SCADA Software, versions prior to Version 3.02.01. An uncontrolled search path element (DLL Hijacking) vulnerability has been identified. Exploitation of this vulnerability could give an attacker access to the system with the same level of privilege as the application that utilizes the malicious DLL. |
| A DLL Hijack issue was discovered in Rockwell Automation Connected Components Workbench (CCW). The following versions are affected: Connected Components Workbench - Developer Edition, v9.01.00 and earlier: 9328-CCWDEVENE, 9328-CCWDEVZHE, 9328-CCWDEVFRE, 9328-CCWDEVITE, 9328-CCWDEVDEE, 9328-CCWDEVESE, and 9328-CCWDEVPTE; and Connected Components Workbench - Free Standard Edition (All Supported Languages), v9.01.00 and earlier. Certain DLLs included with versions of CCW software can be potentially hijacked to allow an attacker to gain rights to a victim's affected personal computer. Such access rights can be at the same or potentially higher level of privileges as the compromised user account, including and up to computer administrator privileges. |
| All editions of Rapid7 Nexpose installers prior to version 6.4.24 contain a DLL preloading vulnerability, wherein it is possible for the installer to load a malicious DLL located in the current working directory of the installer. |
| Rapid7 AppSpider Pro installers prior to version 6.14.053 contain a DLL preloading vulnerability, wherein it is possible for the installer to load a malicious DLL located in the current working directory of the installer. |
| Rapid7 Insight Collector installers prior to version 1.0.16 contain a DLL preloading vulnerability, wherein it is possible for the installer to load a malicious DLL located in the current working directory of the installer. |
| Rapid7 Metasploit Pro installers prior to version 4.13.0-2017022101 contain a DLL preloading vulnerability, wherein it is possible for the installer to load a malicious DLL located in the current working directory of the installer. |
| Editions of Rapid7 AppSpider Pro installers prior to version 6.14.060 contain a DLL preloading vulnerability, wherein it is possible for the installer to load a malicious DLL located in the current working directory of the installer. |
| A vulnerability in the build procedure for certain executable system files installed at boot time on Cisco Application Policy Infrastructure Controller (APIC) devices could allow an authenticated, local attacker to gain root-level privileges. The vulnerability is due to a custom executable system file that was built to use relative search paths for libraries without properly validating the library to be loaded. An attacker could exploit this vulnerability by authenticating to the device and loading a malicious library that can escalate the privilege level. A successful exploit could allow the attacker to gain root-level privileges and take full control of the device. The attacker must have valid user credentials to log in to the device. Cisco Bug IDs: CSCvc96087. Known Affected Releases: 1.1(0.920a), 1.1(1j), 1.1(3f); 1.2 Base, 1.2(2), 1.2(3), 1.2.2; 1.3(1), 1.3(2), 1.3(2f); 2.0 Base, 2.0(1). |
| Trend Micro Endpoint Sensor 1.6 before b1290 has a DLL hijacking vulnerability that allows remote attackers to execute arbitrary code, aka Trend Micro Vulnerability Identifier 2015-0208. |
| HedEx Earlier than V200R006C00 versions has a dynamic link library (DLL) hijacking vulnerability due to calling the DDL file by accessing a relative path. An attacker could exploit this vulnerability to tamper with the DLL file, leading to DLL hijacking. |
| An Uncontrolled Search Path Element issue was discovered in Solar Controls Heating Control Downloader (HCDownloader) Version 1.0.1.15 and prior. An uncontrolled search path element has been identified, which could allow an attacker to execute arbitrary code on a target system using a malicious DLL file. |
| An Uncontrolled Search Path Element issue was discovered in Solar Controls WATTConfig M Software Version 2.5.10.1 and prior. An uncontrolled search path element has been identified, which could allow an attacker to execute arbitrary code on a target system using a malicious DLL file. |
| An Uncontrolled Search Path Element issue was discovered in SIMPlight SCADA Software version 4.3.0.27 and prior. The uncontrolled search path element vulnerability has been identified, which may allow an attacker to place a malicious DLL file within the search path resulting in execution of arbitrary code. |
| There exists a path traversal vulnerability in the Android Google Search app. This is caused by the incorrect usage of uri.getLastPathSegment. A symbolic encoded string can bypass the path logic to get access to unintended directories. An attacker can manipulate paths that could lead to code execution on the device. We recommend upgrading beyond version 13.41 |
| An unauthenticated user can access Identity Manager’s management console specific page URLs. However, the system doesn’t allow the user to carry out server side tasks without a valid web session. |
| The tested version of Dominion Voting Systems ImageCast X allows for rebooting into Android Safe Mode, which allows an attacker to directly access the operating system. An attacker could leverage this vulnerability to escalate privileges on a device and/or install malicious code. |
| Missing DLLs, if replaced by an insider, could allow an attacker to achieve local privilege escalation on the DeltaV Distributed Control System Controllers and Workstations (All versions) when some DeltaV services are started. |
| AVEVA Software Platform Common Services (PCS) Portal versions 4.5.2, 4.5.1, 4.5.0, and 4.4.6 are vulnerable to DLL hijacking through an uncontrolled search path element, which may allow an attacker control to one or more locations in the search path. |
| DWG TrueViewTM 2023 version has a DLL Search Order Hijacking vulnerability. Successful exploitation by a malicious attacker could result in remote code execution on the target system. |