Export limit exceeded: 414071 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (4795 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-62765 | 1 General Industrial Controls | 1 Lynx+ Gateway | 2026-04-15 | 7.5 High |
| General Industrial Controls Lynx+ Gateway is vulnerable to a cleartext transmission vulnerability that could allow an attacker to observe network traffic to obtain sensitive information, including plaintext credentials. | ||||
| CVE-2025-59448 | 1 Yosmart | 3 Yolink Hub, Yolink Mobile Application, Yolink Mqtt Broker | 2026-04-15 | 4.7 Medium |
| Components of the YoSmart YoLink ecosystem through 2025-10-02 leverage unencrypted MQTT to communicate over the internet. An attacker with the ability to monitor network traffic could therefore obtain sensitive information or tamper with the traffic to control affected devices. This affects YoLink Hub 0382, YoLink Mobile Application 1.40.41, and YoLink MQTT Broker. NOTE: The vendor states that the vulnerability described (related to insecure transmission) only impacts the legacy mobile application logic, not the Hub hardware or firmware. The Hub functions solely as a pass-through (transparent gateway) for LoRa wireless data and does not inspect or process the application layer data. | ||||
| CVE-2025-59450 | 1 Yosmart | 1 Yolink Smart Hub | 2026-04-15 | 4.3 Medium |
| The YoSmart YoLink Smart Hub firmware 0382 is unencrypted, and data extracted from it can be used to determine network access credentials. | ||||
| CVE-2025-60791 | 1 Easywork | 1 Easywork | 2026-04-15 | 6.2 Medium |
| Easywork Enterprise 2.1.3.354 is vulnerable to Cleartext Storage of Sensitive Information in Memory. The application leaves valid device-bound license keys in process memory after a failed activation attempt. The keys can be obtained by attaching a debugger or analyzing the process/memory dump and then they can be used to activate the software on the same machine without purchasing. | ||||
| CVE-2025-52351 | 2026-04-15 | 8.8 High | ||
| Aikaan IoT management platform v3.25.0325-5-g2e9c59796 sends a newly generated password to users in plaintext via email and also includes the same password as a query parameter in the account activation URL (e.g., https://domain.com/activate=xyz). This practice can result in password exposure via browser history, proxy logs, referrer headers, and email caching. The vulnerability impacts user credential confidentiality during initial onboarding. | ||||
| CVE-2025-50109 | 1 Emerson | 1 Valvelink | 2026-04-15 | 7.7 High |
| Emerson ValveLink Products store sensitive information in cleartext within a resource that might be accessible to another control sphere. | ||||
| CVE-2025-50110 | 2026-04-15 | 8.8 High | ||
| An issue was discovered in the method push.lite.avtech.com.AvtechLib.GetHttpsResponse in AVTECH EagleEyes Lite 2.0.0, the GetHttpsResponse method transmits sensitive information - including internal server URLs, account IDs, passwords, and device tokens - as plaintext query parameters over HTTPS | ||||
| CVE-2025-48428 | 1 Gallagher | 1 Command Centre | 2026-04-15 | 6.7 Medium |
| Cleartext Storage of Sensitive Information (CWE-312) in the Gallagher Morpho integration could allow an authenticated user with access to the Command Centre Server to export a specific signing key while in use allowing them to deploy a compromised or counterfeit device on that site. This issue affects Command Centre Server: 9.20 prior to vEL9.20.2819 (MR4), 9.10 prior to vEL9.10.3672 (MR7), 9.00 prior to vEL9.00.3831 (MR8), all versions of 8.90 and prior. | ||||
| CVE-2025-7731 | 1 Mitsubishi Electric | 1 Melsec Iq-f Series | 2026-04-15 | 7.5 High |
| Cleartext Transmission of Sensitive Information vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU module allows a remote unauthenticated attacker to obtain credential information by intercepting SLMP communication messages, and read or write the device values of the product and stop the operations of programs by using the obtained credential information. | ||||
| CVE-2025-47419 | 2026-04-15 | N/A | ||
| Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic. The device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords. This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49. | ||||
| CVE-2025-4737 | 1 Tecno | 1 Com.transsion.aivoiceassistant | 2026-04-15 | 6.2 Medium |
| Insufficient encryption vulnerability in the mobile application (com.transsion.aivoiceassistant) may lead to the risk of sensitive information leakage. | ||||
| CVE-2025-4394 | 2026-04-15 | 6.8 Medium | ||
| Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025 | ||||
| CVE-2025-40752 | 1 Siemens | 2 Q100, Q200 | 2026-04-15 | 6.2 Medium |
| A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes. | ||||
| CVE-2025-32875 | 2026-04-15 | 5.7 Medium | ||
| An issue was discovered in the COROS application through 3.8.12 for Android. Bluetooth pairing and bonding is neither initiated nor enforced by the application itself. Also, the watch does not enforce pairing and bonding. As a result, any data transmitted via BLE remains unencrypted, allowing attackers within Bluetooth range to eavesdrop on the communication. Furthermore, even if a user manually initiates pairing and bonding in the Android settings, the application continues to transmit data without requiring the watch to be bonded. This fallback behavior enables attackers to exploit the communication, for example, by conducting an active machine-in-the-middle attack. | ||||
| CVE-2025-27594 | 2026-04-15 | 7.5 High | ||
| The device uses an unencrypted, proprietary protocol for communication. Through this protocol, configuration data is transmitted and device authentication is performed. An attacker can thereby intercept the authentication hash and use it to log into the device using a pass-the-hash attack. | ||||
| CVE-2025-23027 | 2026-04-15 | N/A | ||
| next-forge is a Next.js project boilerplate for modern web application. The BASEHUB_TOKEN commited in apps/web/.env.example. Users should avoid use of this token and should remove any access it may have in their systems. | ||||
| CVE-2025-10641 | 1 Efficientlab | 1 Workexaminer Professional | 2026-04-15 | 7.1 High |
| All WorkExaminer Professional traffic between monitoring client, console and server is transmitted as plain text. This allows an attacker with access to the network to read the transmitted sensitive data. An attacker can also freely modify the data on the wire. The monitoring clients transmit their data to the server using the unencrypted FTP. Clients connect to the FTP server on port 12304 and transmit the data unencrypted. In addition, all traffic between the console client and the server at port 12306 is unencrypted. | ||||
| CVE-2025-2189 | 2026-04-15 | N/A | ||
| This vulnerability exists in the Tinxy smart devices due to storage of credentials in plaintext within the device firmware. An attacker with physical access could exploit this by extracting the firmware and analyzing the binary data to obtain the plaintext credentials stored on the vulnerable device. | ||||
| CVE-2025-22493 | 2026-04-15 | 5.6 Medium | ||
| Secure flag not set and SameSIte was set to Lax in the Foreseer Reporting Software (FRS). Absence of this secure flag could lead into the session cookie being transmitted over unencrypted HTTP connections. This security issue has been resolved in the latest version of FRS v1.5.100. | ||||
| CVE-2024-9991 | 1 Signify Innovations India | 7 Phillips Smart Bulb 10-watt Firmware, Phillips Smart Bulb 12-watt Firmware, Phillips Smart Bulb 9-watt Firmware and 4 more | 2026-04-15 | N/A |
| This vulnerability exists in Philips lighting devices due to storage of Wi-Fi credentials in plain text within the device firmware. An attacker with physical access could exploit this by extracting the firmware and analyzing the binary data to obtain the plaintext Wi-Fi credentials stored on the vulnerable device. Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access to the Wi-Fi network to which vulnerable device is connected. | ||||