| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A flaw was found in the Keycloak Admin REST API. This vulnerability allows the exposure of backend schema and rules, potentially leading to targeted attacks or privilege escalation via improper access control. |
| A flaw was found in the Open Virtual Network (OVN). Specially crafted UDP packets may bypass egress access control lists (ACLs) in OVN installations configured with a logical switch with DNS records set on it and if the same switch has any egress ACLs configured. This issue can lead to unauthorized access to virtual machines and containers running on the OVN network. |
| A "Privilege boundary violation" vulnerability is identified affecting multiple Radiometer Products. Exploitation of this vulnerability gives a user with physical access to the analyzer, the possibility to gain unauthorized access to functionalities outside the restricted environment. The vulnerability is due to weakness in the design of access control implementation in application software.
Other related CVE's are CVE-2025-14096 & CVE-2025-14097.
Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.
Required configuration for Exposure:
Physical access to the analyzer is needed.
Temporary work Around:
Only authorized people can physically access the analyzer.
Permanent solution:
Local Radiometer representatives will contact all affected customers to discuss a permanent solution.
Exploit Status:
Researchers have provided working proof-of-concept. Radiometer is not aware of any publicly available exploit at the time of publication. Note:
CVSS score 6.8 when underlying OS is Windows 7 or Windows XP Operating systems and CVSS score 5.7 when underlying OS is Windows 8 or Windows 10 operating systems. |
| Incorrect access control in the dynawebservice component of agorum Software GmbH Agorum core open v11.9.2 & v11.10.1 allows unauthenticated attackers to access arbitrary files on the system. |
| Incorrect access control in Software GmbH Agorum core open v11.9.2 & v11.10.1 allows authenticated attackers to escalate privileges to Administrator and access sensitive components and information. |
| linjiashop <=0.9 is vulnerable to Incorrect Access Control. When using the default-generated JWT authentication, attackers can bypass the authentication and retrieve the encrypted "password" and "salt". The password can then be obtained through brute-force cracking. |
| Improper access control for some Intel(R) Graphics software may allow an authenticated user to potentially enable denial of service via local access. |
| Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down. |
| A security vulnerability has been detected in Verysync 微力同步 up to 2.21.3. The impacted element is an unknown function of the file /rest/f/api/resources/f96956469e7be39d of the component Web Administration Module. Such manipulation leads to information disclosure. The attack can be executed remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability classified as critical has been found in 299Ko CMS 2.0.0. This affects an unknown part of the file /admin/filemanager/view of the component File Management. The manipulation leads to unrestricted upload. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| An Insecure Direct Object Reference (IDOR) vulnerability was identified in the `POST /v1/templates` endpoint of the Lunary API, affecting versions up to 0.8.8. This vulnerability allows authenticated users to create templates in another user's project by altering the `projectId` query parameter. The root cause of this issue is the absence of server-side validation to ensure that the authenticated user owns the specified `projectId`. The vulnerability has been addressed in version 1.9.23. |
| Northern.tech Mender Server before 3.7.11 and 4.x before 4.0.1 has Incorrect Access Control. |
| A vulnerability was found in Intelbras VIP S3020 G2, VIP S4020 G2, VIP S4020 G3 and VIP S4320 G2 up to 20241222 and classified as problematic. Affected by this issue is some unknown functionality of the file /web_caps/webCapsConfig of the component Web Interface. The manipulation leads to information disclosure. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor assesses that "the information disclosed in the URL is not sensitive or poses any risk to the user". |
| goshs is a SimpleHTTPServer written in Go. Starting in version 0.3.4 and prior to version 1.0.5, running goshs without arguments makes it possible for anyone to execute commands on the server. The function `dispatchReadPump` does not checks the option cli `-c`, thus allowing anyone to execute arbitrary command through the use of websockets. Version 1.0.5 fixes the issue. |
| Lavasoft Web Companion (also known as Ad-Aware WebCompanion) versions 8.9.0.1091 through 12.1.3.1037 installs the DCIService.exe service with an unquoted service path vulnerability. An attacker with write access to the file system could potentially execute arbitrary code with elevated privileges by placing a malicious executable in the unquoted path. |
| Misconfigured settings in IITB SSO v1.1.0 allow attackers to access sensitive application data. |
| Texas Instruments CC2652RB LaunchPad SimpleLink CC13XX CC26XX SDK 7.41.00.17 was discovered to utilize insufficient permission checks on critical fields within Bluetooth Low Energy (BLE) data packets. This issue allows attackers to cause a Denial of Service (DoS) via a crafted LL_Length_Req packet. |
| DASAN GPON ONU H660WM H660WMR210825 is susceptible to improper access control under its default settings. Attackers can exploit this vulnerability to gain unauthorized access to sensitive information and modify its configuration via the UPnP protocol WAN sides without any authentication. |
| A vulnerability, which was classified as problematic, was found in Shenzhen Sixun Software Sixun Shanghui Group Business Management System 7. This affects an unknown part of the file /api/GylOperator/LoadData. The manipulation leads to information disclosure. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. |
| There is no memory isolation between CPU cores of the MIB3 infotainment. This fact allows an attacker with access to the main operating system to compromise the CPU core responsible for CAN message processing.
The vulnerability was originally discovered in Skoda Superb III car with MIB3 infotainment unit OEM part number 3V0035820. The list of affected MIB3 OEM part numbers is provided in the referenced resources. |