| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| CWE-798: Use of Hard-coded Credentials |
| An unauthenticated remote attacker can use hard-coded credentials to gain full administration privileges on the affected product. |
| The firmware of all Wattsense Bridge devices contain the same hard-coded user and root credentials. The user password can be easily recovered via password cracking attempts. The recovered credentials can be used to log into the device via the login shell that is exposed by the serial interface. The backdoor user has been removed in firmware BSP >= 6.4.1. |
| A predefined administrative account is not documented and cannot
be deactivated. This account cannot be misused from the network, only by local
users on the server. |
| The program libraries (DLL) and binaries used by exos 9300 contain multiple hard-coded secrets. One notable example is the function "EncryptAndDecrypt" in the library Kaba.EXOS.common.dll. This algorithm uses a simple XOR encryption technique combined with a cryptographic key (cryptoKey) to transform each character of the input string. However, it's important to note that this implementation does not provide strong encryption and should not be considered secure for sensitive data. It's more of a custom encryption approach rather than a common algorithm used in cryptographic applications. The key itself is static and based on the founder's name of the company. The functionality is for example used to encrypt the user PINs before storing them in the MSSQL database. |
| Vulnerabilities* in ActADUR local server product, developed and maintained by ProTNS, allows Remote Code Inclusion on host systems.
* vulnerabilities:
*
Improper Neutralization of Special Elements used in a Command ('Command Injection')
* Use of Hard-coded Credentials
* Improper Authentication
* Binding to an Unrestricted IP Address
The vulnerability has been rated as critical.This issue affects ActADUR: from v2.0.1.9 before v2.0.2.0., hence updating to version v2.0.2.0. or above is required. |
| The wsc server uses a hard-coded certificate to check the authenticity of SOAP messages. An unauthenticated remote attacker can extract private keys from the Software of the affected devices. |
| Shenzhen Tuoshi NR500-EA RG500UEAABxCOMSLICv3.4.2731.16.43 devices enable the SSH service by default. There is a hidden hard-coded root account that cannot be disabled in the GUI. |
| Certain Draytek products are affected by Insecure Configuration. This affects AP903 v1.4.18 and AP912C v1.4.9 and AP918R v1.4.9. The setting of the password property in the ripd.conf configuration file sets a hardcoded weak password, posing a security risk. An attacker with network access could exploit this to gain unauthorized control over the routing daemon, potentially altering network routes or intercepting traffic. |
| UNI-NMS-Lite uses hard-coded credentials that could allow an
unauthenticated attacker to read, manipulate and create entries in the
managed database. |
| Default credentials were present in the web portal for Airpointer 2.4.107-2, allowing an unauthenticated malicious actor to log in via the web portal |
| The CS5000 Fire Panel is vulnerable due to a hard-coded password that
runs on a VNC server and is visible as a string in the binary
responsible for running VNC. This password cannot be altered, allowing
anyone with knowledge of it to gain remote access to the panel. Such
access could enable an attacker to operate the panel remotely,
potentially putting the fire panel into a non-functional state and
causing serious safety issues. |
| Cypress Solutions CTM-200/CTM-ONE 1.3.6 contains hard-coded credentials vulnerability in Linux distribution that exposes root access. Attackers can exploit the static 'Chameleon' password to gain remote root access via Telnet or SSH on affected devices. |
| Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to disclose information such as generated power and electricity sold back to the grid stored in the product, tamper with or destroy stored or configured information in the product, or cause a Denial-of-Service (DoS) condition on the product, by using hardcoded user ID and password common to the product series obtained by exploiting CVE-2025-5022. The affected products discontinued in 2015, support ended in 2020. |
| Infoblox BloxOne v2.4 was discovered to contain a business logic flaw due to thick client vulnerabilities. |
| Use of hard-coded credentials issue exists in ZWX-2000CSW2-HN prior to 0.3.19 and ZWX-2000CS2-HN firmware all versions. If this vulnerability is exploited, an attacker may tamper with the settings of the device by obtaining the credentials. This vulnerability is caused by an insufficient fix for CVE-2024-39838. |
| This vulnerability exists in ZKTeco WL20 due to hard-coded MQTT credentials and endpoints stored in plaintext within the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and analyzing the binary data to retrieve the hard-coded MQTT credentials and endpoints from the targeted device.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the MQTT broker and manipulate the communications of the targeted device. |
| onion-site-template is a complete, scalable tor hidden service self-hosting sample. Versions which include commit 3196bd89 contain a baked-in tor image if the secrets were copied from an existing onion domain. A website could be compromised if a user shared the baked-in image, or if someone were able to acquire access to the user's device outside of a containerized environment. This is fixed by commit bc9ba0fd. |
| CWE-798 Use of Hard-coded Credentials |
| api is a module for FreePBX@, which is an open source GUI that controls and manages Asterisk© (PBX). In versions lower than 15.0.13, 16.0.2 through 16.0.14, 17.0.1 and 17.0.2, there is an identical OAuth private key used across multiple systems that installed the same FreePBX RPM or DEB package. An attacker with access to the shared OAuth private key could forge JWT tokens, bypass authentication, and potentially gain full access to both REST and GraphQL APIs. Systems with the "api" module enabled, configured and previously activated by an administrator for remote inbound connections may be affected. This issue is fixed in versions 15.0.13, 16.0.15 and 17.0.3. |