Search Results (8845 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-53107 2026-04-15 7.5 High
@cyanheads/git-mcp-server is an MCP server designed to interact with Git repositories. Prior to version 2.1.5, there is a command injection vulnerability caused by the unsanitized use of input parameters within a call to child_process.exec, enabling an attacker to inject arbitrary system commands. Successful exploitation can lead to remote code execution under the server process's privileges. The server constructs and executes shell commands using unvalidated user input directly within command-line strings. This introduces the possibility of shell metacharacter injection (|, >, &&, etc.). An MCP Client can be instructed to execute additional actions for example via indirect prompt injection when asked to read git logs. This issue has been patched in version 2.1.5.
CVE-2025-53104 2026-04-15 9.1 Critical
gluestack-ui is a library of copy-pasteable components & patterns crafted with Tailwind CSS (NativeWind). Prior to commit e6b4271, a command injection vulnerability was discovered in the discussion-to-slack.yml GitHub Actions workflow. Untrusted discussion fields (title, body, etc.) were directly interpolated into shell commands in a run: block. An attacker could craft a malicious GitHub Discussion title or body (e.g., $(curl ...)) to execute arbitrary shell commands on the Actions runner. This issue has been fixed in commit e6b4271 where the discussion-to-slack.yml workflow was removed. Users should remove the discussion-to-slack.yml workflow if using a fork or derivative of this repository.
CVE-2025-5106 2026-04-15 7.3 High
A vulnerability was found in Fujian Kelixun 1.0. It has been classified as critical. This affects an unknown part of the file /app/fax/fax_view.php of the component Filename Handler. The manipulation of the argument fax_file leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-50891 2026-04-15 7.2 High
The server-side backend for Adform Site Tracking before 2025-08-28 allows attackers to inject HTML or execute arbitrary code via cookie hijacking. NOTE: a customer does not need to take any action to update locally installed software (such as Adform Site Tracking 1.1).
CVE-2025-50817 1 Python 1 Python 2026-04-15 5.4 Medium
A vulnerability in the Python-Future 1.0.0 module allows for arbitrary code execution via the unintended import of a file named test.py. When the module is loaded, it automatically imports test.py, if present in the same directory or in the sys.path. This behavior can be exploited by an attacker who has the ability to write files to the server, allowing the execution of arbitrary code. NOTE: Multiple third parties have disputed this issue and stated that it is not a security flaw in python-future and is a documented feature of Python’s import system in the handling of sys.path.
CVE-2025-50515 2026-04-15 6.5 Medium
An issue was discovered in phome Empirebak 2010 in ebak2008/upload/class/config.php allowing attackers to execute arbitrary code when the config file was loaded.
CVE-2025-50461 2026-04-15 6.5 Medium
A deserialization vulnerability exists in Volcengine's verl 3.0.0, specifically in the scripts/model_merger.py script when using the "fsdp" backend. The script calls torch.load() with weights_only=False on user-supplied .pt files, allowing attackers to execute arbitrary code if a maliciously crafted model file is loaded. An attacker can exploit this by convincing a victim to download and place a malicious model file in a local directory with a specific filename pattern. This vulnerability may lead to arbitrary code execution with the privileges of the user running the script.
CVE-2025-49140 2026-04-15 7.5 High
Pion Interceptor is a framework for building RTP/RTCP communication software. Versions v0.1.36 through v0.1.38 contain a bug in a RTP packet factory that can be exploited to trigger a panic with Pion based SFU via crafted RTP packets, This only affect users that use pion/interceptor. Users should upgrade to v0.1.39 or later, which validates that: `padLen > 0 && padLen <= payloadLength` and return error on overflow, avoiding panic. If upgrading is not possible, apply the patch from the pull request manually or drop packets whose P-bit is set but whose padLen is zero or larger than the remaining payload.
CVE-2025-48978 1 Ui 1 Edgeswitch 2026-04-15 7.5 High
An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.11.0 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network. Affected Products: EdgeMAX EdgeSwitch (Version 1.11.0 and earlier) Mitigation: Update the EdgeMAX EdgeSwitch to Version 1.11.1 or later.
CVE-2025-47188 2026-04-15 6.5 Medium
A vulnerability in the Mitel 6800 Series, 6900 Series, and 6900w Series SIP Phones through 6.4 SP4 (R6.4.0.4006), and the 6970 Conference Unit through 6.4 SP4 (R6.4.0.4006) or version V1 R0.1.0, could allow an unauthenticated attacker to conduct a command injection attack due to insufficient parameter sanitization. A successful exploit could allow an attacker to execute arbitrary commands within the context of the phone, leading to disclosure or modification of sensitive configuration data or affecting device availability and operation.
CVE-2025-4653 2026-04-15 N/A
Improper Neutralization of Special Elements in the backup name field may allow OS command injection. This issue affects Pandora ITSM 5.0.105.
CVE-2025-4076 2026-04-15 6.3 Medium
A vulnerability classified as critical has been found in LB-LINK BL-AC3600 up to 1.0.22. This affects the function easy_uci_set_option_string_0 of the file /cgi-bin/lighttpd.cgi of the component Password Handler. The manipulation of the argument routepwd leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-40570 1 Siemens 1 Siprotec 5 2026-04-15 2.4 Low
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V10.0), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V10.0), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SD82 (CP150) (All versions < V10.0), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SJ81 (CP150) (All versions < V10.0), SIPROTEC 5 7SJ82 (CP150) (All versions < V10.0), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SK82 (CP150) (All versions < V10.0), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SL82 (CP150) (All versions < V10.0), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7ST85 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7SX82 (CP150) (All versions < V10.0), SIPROTEC 5 7SX85 (CP300) (All versions < V10.0), SIPROTEC 5 7SY82 (CP150) (All versions < V10.0), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT82 (CP150) (All versions < V10.0), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VU85 (CP300) (All versions < V10.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V10.0). Affected devices do not properly limit the bandwidth for incoming network packets over their local USB port. This could allow an attacker with physical access to send specially crafted packets with high bandwidth to the affected devices thus forcing them to exhaust their memory and stop responding to any network traffic via the local USB port. Affected devices reset themselves automatically after a successful attack. The protection function is not affected of this vulnerability.
CVE-2025-37166 1 Hpe 1 Aruba Instant On 2026-04-15 7.5 High
A vulnerability affecting HPE Networking Instant On Access Points has been identified where a device processing a specially crafted packet could enter a non-responsive state, in some cases requiring a hard reset to re-establish services. A malicious actor could leverage this vulnerability to conduct a Denial-of-Service attack on a target network.
CVE-2025-37146 1 Hpe 1 Arubaos 2026-04-15 7.2 High
A vulnerability in the web-based management interface of network access point configuration services could allow an authenticated remote attacker to perform remote command execution. Successful exploitation could allow an attacker to execute arbitrary commands on the underlying operating system.
CVE-2025-37102 2026-04-15 7.2 High
An authenticated command injection vulnerability exists in the Command line interface of HPE Networking Instant On Access Points. A successful exploitation could allow a remote attacker with elevated privileges to execute arbitrary commands on the underlying operating system as a highly privileged user.
CVE-2025-32380 2026-04-15 7.5 High
The Apollo Router Core is a configurable, high-performance graph router written in Rust to run a federated supergraph that uses Apollo Federation 2. A vulnerability in Apollo Router's usage of Apollo Compiler allowed queries with deeply nested and reused named fragments to be prohibitively expensive to validate. This could lead to excessive resource consumption and denial of service. Apollo Router's usage of Apollo Compiler has been updated so that validation logic processes each named fragment only once, preventing redundant traversal. This has been remediated in apollo-router versions 1.61.2 and 2.1.1.
CVE-2025-29628 2026-04-15 9.4 Critical
A Gardyn Azure IoT Hub connection string is downloaded over an insecure HTTP connection in Gardyn Home Kit firmware before master.619, Home Kit Mobile Application before 2.11.0, and Home Kit Cloud API before 2.12.2026 leaving the string vulnerable to interception and modification through a Man-in-the-Middle attack. This may result in the attacker capturing device credentials or taking control of vulnerable home kits.
CVE-2025-29509 2026-04-15 8.8 High
Jan v0.5.14 and before is vulnerable to remote code execution (RCE) when the user clicks on a rendered link in the conversation, due to opening external website in the app and the exposure of electronAPI, with a lack of filtering of URL when calling shell.openExternal().
CVE-2025-2916 2026-04-15 6.3 Medium
A vulnerability, which was classified as critical, has been found in Aishida Call Center System up to 20250314. This issue affects some unknown processing of the file /doscall/weixin/open/amr2mp3. The manipulation of the argument File leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.