| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). There is a missing authentication verification for a resource used to change the roles and permissions of a user. This could allow an attacker to change the permissions of any user and gain the privileges of an administrative user. |
| A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker in a Man-in-the-Middle position between the SiPass integrated server and SiPass integrated clients to read or modify the network communication. |
| A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack on the integrated web server on port 443/tcp. |
| A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server. |
| The 'Find Phone' function in Nice smartphones with software versions earlier before Nice-AL00C00B0135 has an authentication bypass vulnerability. An unauthenticated attacker may wipe and factory reset the phone by special steps. Due to missing authentication of the 'Find Phone' function, an attacker may exploit the vulnerability to bypass the 'Find Phone' function in order to use the phone normally. |
| A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker with access to port 21/tcp to access or alter historical measurement data stored on the device. |
| rkhunter versions before 1.4.4 are vulnerable to file download over insecure channel when doing mirror update resulting into potential remote code execution. |
| IBM BigFix Compliance (TEMA SUAv1 SCA SCM) uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 123672. |
| A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2). The existing TLS protocol implementation could allow an attacker to read and modify data within a TLS session while performing a Man-in-the-Middle (MitM) attack. |
| An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. CADD-Solis Medication Safety Software grants an authenticated user elevated privileges on the SQL database, which would allow an authenticated user to modify drug libraries, add and delete users, and change user permissions. According to Smiths-Medical, physical access to the pump is required to install drug library updates. |
| An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration. |
| Crypto-NAK packets in ntpd in NTP 4.2.x before 4.2.8p4, and 4.3.x before 4.3.77 allows remote attackers to bypass authentication. |
| In all Android releases from CAF using the Linux kernel, the Hypervisor API could be misused to bypass authentication. |
| The outdoor unit of Customer Premise Equipment (CPE) product B2338-168 V100R001C00 has a no authentication vulnerability on the serial port. An attacker can access the serial port on the circuit board of the outdoor unit and log in to the CPE without authentication. Successful exploit could allow the attacker to take control over the outdoor unit. |
| The outdoor unit of Customer Premise Equipment (CPE) product B2338-168 V100R001C00 has a no authentication vulnerability on a certain port. After accessing the network between the indoor and outdoor units of the CPE, an attacker can deliver commands to the specific port of the outdoor unit and execute them without authentication. Successful exploit could allow the attacker to take control over the outdoor unit. |
| An issue was discovered on Humax Digital HG100R 2.0.6 devices. To download the backup file it's not necessary to use credentials, and the router credentials are stored in plaintext inside the backup, aka GatewaySettings.bin. |
| An Improper Authorization issue was discovered in Sierra Wireless AirLink Raven XE, all versions prior to 4.0.14, and AirLink Raven XT, all versions prior to 4.0.11. Several files and directories can be accessed without authentication, which may allow a remote attacker to perform sensitive functions including arbitrary file upload, file download, and device reboot. |
| Two four letter word commands "wchp/wchc" are CPU intensive and could cause spike of CPU utilization on Apache ZooKeeper server if abused, which leads to the server unable to serve legitimate client requests. Apache ZooKeeper thru version 3.4.9 and 3.5.2 suffer from this issue, fixed in 3.4.10, 3.5.3, and later. |
| Exploitation of Authentication vulnerability in the web interface in McAfee Advanced Threat Defense (ATD) 3.10, 3.8, 3.6, 3.4 allows remote unauthenticated users / remote attackers to bypass ATD detection via loose enforcement of authentication and authorization. |
| Authentication Bypass vulnerability in the web interface in McAfee Advanced Threat Defense (ATD) 3.10, 3.8, 3.6, 3.4 allows remote unauthenticated users / remote attackers to change or update any configuration settings, or gain administrator functionality via a crafted HTTP request parameter. |