| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| PWAsForFirefox is a tool to install, manage and use Progressive Web Apps (PWAs) in Mozilla Firefox. Due to improper sanitization of web app properties (such as name, description, shortcuts), web apps were able to inject additional lines into XDG Desktop Entries (on Linux) and `AppInfo.ini` (on PortableApps.com). This allowed malicious web apps to introduce keys like `Exec`, which could run arbitrary code when the affected web app was launched. This vulnerability affects all Linux and PortableApps.com users of all PWAsForFirefox versions up to (excluding) 2.12.0. Windows and macOS users are not affected. This vulnerability has been fixed in commit `9932d4b` which has been included in release in v2.12.0. The main fix is implemented in the native part, but the extension also contains additional fixes. All Linux and PortableApps.com users are advised to update to this version as soon as possible. It is also recommended for Windows and macOS users to update to this version, as it contains additional fixes related to properties sanitization. There are no known workarounds for this vulnerability. |
| The Tillitis TKey signer device application is an ed25519 signing tool. A vulnerability has been found that makes it possible to disclose portions of the TKey’s data in RAM over the USB interface. To exploit the vulnerability an attacker needs to use a custom client application and to touch the TKey. No secret is disclosed. All client applications integrating tkey-device-signer should upgrade to version 1.0.0 to receive a fix. No known workarounds are available. |
| A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server. |
| MariaDB Server 10.4 through 10.5.*, 10.6 through 10.6.*, 10.7 through 10.11.*, and 11.0 through 11.0.* can sometimes crash with an empty backtrace log. This may be related to make_aggr_tables_info and optimize_stage2. |
| MariaDB Server 10.4 through 10.5.*, 10.6 through 10.6.*, 10.7 through 10.11.*, 11.0 through 11.0.*, and 11.1 through 11.4.* crashes in Item_direct_view_ref::derived_field_transformer_for_where. |
| MariaDB Server 10.10 through 10.11.* and 11.0 through 11.4.* crashes in JOIN::fix_all_splittings_in_plan. |
| Server receiving a malformed message that where the GCL message hostname may be too large which may cause a stack overflow; resulting in possible remote code execution. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.
|
| C300 information leak due to an analysis feature which allows extracting more memory over the network than required by the function. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.
|
| Server receiving a malformed message that causes a disconnect to a hostname may causing a stack overflow resulting in possible remote code execution. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.
|
| Server receiving a malformed message that uses the hostname in an internal table may cause a stack overflow resulting in possible remote code execution. See Honeywell Security Notification for recommendations on upgrading and versioning.
|
| Server receiving a malformed message based on a list of IPs resulting in heap corruption causing a denial of service. See Honeywell Security Notification for recommendations on upgrading and versioning.
|
| Server receiving a malformed message based on a using the specified key values can cause a heap overflow vulnerability which could lead to an attacker performing remote code execution or causing a failure.
See Honeywell Security Notification for recommendations on upgrading and versioning.
|
| Server receiving a malformed message based on a using the specified key values can cause a stack overflow vulnerability which could lead to an attacker performing remote code execution or causing a failure. See Honeywell Security Notification for recommendations on upgrading and versioning.
|
| Server receiving a malformed message can cause a pointer to be overwritten which can result in a remote code execution or failure. See Honeywell Security Notification for recommendations on upgrading and versioning. |
| Controller denial of service due to improper handling of a specially crafted message received by the controller.
See Honeywell Security Notification for recommendations on upgrading and versioning. |
|
Vladimir Kononovich, a Security Researcher has found a flaw that allows for a remote code execution on the DVR. An attacker could inject malicious HTTP headers into request packets to execute arbitrary code. The manufacturer has released patch firmware for the flaw, please refer to the manufacturer's report for details and workarounds.
|
|
Team ENVY, a Security Research TEAM has found a flaw that allows for a remote code execution on the camera. An attacker could inject malicious into http request packets to execute arbitrary code. The manufacturer has released patch firmware for the flaw, please refer to the manufacturer's report for details and workarounds.
|
| A vulnerability has been discovered in Winhex affecting version 16.1 SR-1 and 20.4. This vulnerability consists of a buffer overflow controlling the Structured Exception Handler (SEH) registers. This could allow attackers to execute arbitrary code via a long filename argument. |
| A vulnerability has been discovered in Winhex affecting version 16.1 SR-1 and 20.4. This vulnerability consists of a buffer overflow controlling the Structured Exception Handler (SEH) registers. This could allow attackers to execute arbitrary code via a long filename argument. |
| Sandro Poppi, member of the AXIS OS Bug Bounty Program, has found that the VAPIX APIs local_list.cgi, create_overlay.cgi and irissetup.cgi was vulnerable for file globbing which could lead to a resource exhaustion attack. Axis has released patched AXIS OS
versions for the highlighted flaw. Please refer to the Axis security advisory
for more information and solution. |